Burlington allows up to three additional residential units on an urban residential lot. The first one, usually the basement apartment, needs zero extra parking spaces, and the main house keeps its two. Zoning allows only one exterior entrance on each wall that faces a street and sets no minimum unit size, so the basement door usually goes on the side or back, and the Ontario Building Code's ceiling height, egress and fire rules decide what fits. The City checks parking, entrances and the unit layout with a Zoning Clearance Certificate before you can apply for a building permit.
- First ARU: 0 parking spaces. Second and third ARU: 1 space each. Main house: 2 spaces.
- Only one exterior entrance is allowed on each wall of the house that faces a street.
- Zoning sets no minimum floor area. The Building Code sets the ceiling height: at least 1.95 m in the suite and 1.85 m under beams and ducts.
- Burlington now has two residential zoning by-laws in force, so first check which one covers your lot.
- You need a Zoning Clearance Certificate before the building permit. The City may cover eligible fees.
What counts as an additional residential unit in Burlington
The City defines ARUs as self-contained units with their own kitchen, bathroom and sleeping areas on the same property as a detached house, semi or townhouse. A basement apartment is the most common type. Garage conversions, additions and backyard units also count.
The limit went up recently. On January 28, 2025, Council approved OPA 3 and a zoning amendment allowing four units as-of-right: the main home plus three ARUs. In practice, most of our Burlington clients build one unit in the basement and keep the option of adding a second later.
The City also warns that "not all properties will be able to have additional residential units." Lot width, driveway space and grading usually decide it.
Two zoning by-laws, so check yours first
Burlington now has two zoning by-laws in effect: the new Residential Zoning By-law 09-2026, in force since March 2, 2026, and the older Zoning By-law 2020. Some rules are worded differently depending on which one covers your lot. We confirm which by-law applies to the address before anyone draws a floor plan. Many of the City's ARU handouts were written under By-law 2020, so read them with that in mind.
Parking: how many spaces and where they can go
The City's ARU page sets out the count: two spaces for the primary home, zero for the first ARU, plus one each for a second or third ARU. The new by-law sets the same counts and a minimum space size of 2.75 m wide and 16.5 square metres in area.
| Units on the lot | Spaces required | What this usually means on site |
|---|---|---|
| Main house only | 2 | Single garage plus driveway, or a double driveway |
| Main house + basement apartment | 2 (0 for the ARU) | No driveway changes needed for parking |
| Main house + 2 ARUs | 3 | Often needs tandem parking or a wider driveway, where allowed |
| Main house + 3 ARUs | 4 | Only realistic on wider lots or with a rear lane |
A few details in the City's ARU zoning FAQ and drawing checklist affect real projects:
- Tandem parking is permitted, so cars parked one behind the other on a long driveway count.
- Spaces have to sit fully inside your property line, and the site plan has to show the dimensions of each one.
- Under By-law 2020, walkways can count toward a parking space's area for residential uses. That helps on tight lots.
Converting the garage has a knock-on effect. A lawfully existing attached garage can become an ARU, but you lose the garage parking space. The main house's two spaces still have to fit somewhere else on the lot.
Entrances: where the basement door can go
No rule shapes basement layouts more than this one. The ARU amendment to By-law 2020 says only one exterior entrance is permitted "on each elevation of the principal building facing a street." The same rule appears in the City's Part 1 general provisions. If the main door is already on the front wall, the basement door has to go on a side or rear wall. On a corner lot, the flanking side also faces a street, so the limit applies there too.
A separate door isn't always required. The City's checklist asks you to show each unit's exterior entrance and whether it is exclusive or shared. The 2024 Ontario Building Code also lets the units in a house with a secondary suite share a single means of egress if the fire protection is done properly.
| Entrance option | Zoning fit | What we watch for |
|---|---|---|
| Shared front door with an inside vestibule | No new street-facing door | Fire separation or smoke-tight barrier at the vestibule, plus tenant privacy |
| Existing side door to the landing | Usually fine on an interior lot | Headroom over the basement stair and separating the landing from the upstairs unit |
| New side-yard walk-up stair | Fine on an interior lot | Side-yard width, drainage at the foot of the stair, gas and hydro meters, the neighbour's grade |
| Rear walkout | Not street-facing on most lots | Excavation, retaining walls, grading and drainage review |
The new by-law adds entrance rules of its own. In several low-rise zones it limits how high above grade a pedestrian entrance facing the front can sit. If your lot falls under By-law 09-2026, we check those limits before choosing a door location.
Size: zoning is flexible, the Building Code is not
Zoning doesn't restrict size much. Under the 2025 amendment, minimum floor area per dwelling unit and minimum floor area ratio do not apply to lots with ARUs. ARUs also aren't counted toward maximum density.
An old City checklist may tell you something different. The July 2021 accessory unit checklist capped the unit at 40% of the building's floor area and required one parking space. That document predates the amendments that cut first-unit parking to zero. Go by the current FAQ and confirm with zoning staff.
In practice, the Building Code is what limits size. Under the 2024 Code, ceilings in secondary suites must be at least 1.95 m, with 1.85 m under beams and ducts. Other Code items that change a layout:
- Bedroom egress. A bedroom needs an egress window unless there's a walkout or walk-up stair. If the window opens into a window well, you need at least 550 mm of clearance in front of the window.
- Fire protection between units. The Code drops the fire separation requirement if walls and floor framing are covered by a continuous smoke-tight barrier of 15.9 mm Type X gypsum board. Sound rating rules still apply.
- Entrance door size. The suite entrance door must be at least 810 mm wide and 1980 mm high.
What the City reviews before a permit
Burlington has a step many homeowners don't expect. You need an approved Zoning Clearance Certificate before you can apply for a building permit, and the certificate expires one year after it's issued.
- Check the rules. Confirm your zone and which by-law applies. The City's ARU look-up tool covers detached units.
- Zoning clearance. The site plan shows each parking space with dimensions and every exterior entrance. The floor plans outline the ARU. The elevations show the location of the separate exterior entrance. Include a tree permit or a grading and drainage certificate if the work needs one. You email the package to [email protected].
- Building permit. The permit drawings cover fire protection, egress, ceiling heights, HVAC, plumbing and structure. The application goes to [email protected].
- Inspections and occupancy. Framing, insulation, fire protection and final inspections, then occupancy.
One exception: since January 1, 2025, you can apply for the building permit before the zoning certificate if the ARU is in an accessory building. Basement units still follow the standard order.
Fees and incentives
The City pays up to 100% of eligible municipal fees for homeowners, including zoning clearance, building permit, occupancy and inspection fees. Units inside the house can also get up to $70,000 per new affordable rental unit. That money starts as a loan and becomes a grant if the unit stays affordable for 10 years. Read the affordability terms before you count on it.
What we see on site
When a Burlington basement apartment stalls, it's usually for one of these reasons:
- Nobody measured the ceiling height properly. We measure to the bottom of the lowest duct, beam and drain line, not just the joists. A basement that measures 2.0 m at the joists can drop below 1.85 m under a trunk duct. Moving ductwork costs little on paper and a lot once the drywall is up.
- The side yard is too tight for a walk-up. Older Burlington bungalows often have a narrow side yard with the gas meter on it. Cutting a stair there means moving the meter, adding a drain at the bottom and installing a guard. Sometimes a shared vestibule at the existing side door is cleaner and cheaper.
- The furnace room gets missed. If both units share the mechanical room, it has to be part of the fire protection plan from day one, not patched after the framing inspection.
- Parking for a second ARU is an afterthought. If you plan a second unit later, lay out the tandem space now and confirm it measures at least 2.75 m wide and 16.5 m² inside your property line.
We settle the entrance and the ceiling height first, before the kitchen layout. Those two decisions control the zoning drawings, the Code path and most of the budget. Our published range for basement renovations is $25,000 to $100,000+ before HST. Legal units that need a new entrance, egress windows and fire protection usually land in the upper part of that range. Our basement renovation cost guide for Burlington breaks down where the money goes.
A practical next step
Start with three facts about your house: which by-law covers the lot, the lowest ceiling height in the basement, and where a second door could go. Once you have those, the rest of the design follows. Our page on legal basement apartments in Burlington walks through the whole process, from zoning clearance to occupancy. If you're comparing towns or just starting out, our general guide to legal basement apartments goes deeper into the Code side.